Brand Name : Corrtest

Model Number : CS350M

Certification : CE, ISO9001

Place of Origin : Wuhan, China

MOQ : 1set

Price : Negotiable

Payment Terms : T/T, D/P

Supply Ability : 1000set/year

Delivery Time : 5-10 working days

Packaging Details : standard Box

Built-in EIS/FRA, EIS Frequency range : 10μHz~1MHz

Current control range : ±2A

Potential control range : ±10V

Compliance voltage : ±21V

Potential resolution : 10μV

Current resolution : 1pA

Name : Potentiostat Galvanostat

Contact Now

Corrosion Testing Potentiodynamic Polarization Potentiostat Galvanostat CS350M

Corrosion testing potentiodynamic potentiostat galvanostat CS350M consists of DDS arbitrary function generator, high power potentiostat, galvanostat, dual-channel correlation analyzer, dual-channel high-speed 16bit/high-precision 24bit AD converter and extension interfaces. Max. current is ±2A, potential range is ±10V. EIS frequency range is 10uHz~1MHz. It can be used for various electrochemical fields such as corrosion testing, energy, material and electroanalysis. corrosion testing potentiodynamic potentiostat galvanostat CS350M includes all the techniques commonly employed in corrosion testing, such as Open circuit potential (OCP), EIS, potentiodynamic(Tafel plot),Linear polarization curve (LPR), cyclic polarization curve (CPP), Electrochemical Potentiokinetic Reactivation (EPR, )Electrochemical Noise (ECN), Zero resistance Ammeter (ZRA) etc. Corrtest company originated from Corrtest area and

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing

What is potentiodynamic polarization?

The potentiodynamic (polarization curve) test is an electrochemical technique that involves scanning the potential of the working electrode while measuring the corresponding current density. It is also known as the “Tafel plot” which is the most utilized electrochemical method. In this test, the specimens are usually encapsulated in resin with 1 cm2 exposure to the solution. The corrosion rate is measured by potentiodynamic (polarization curve). The potentiodynamic (polarization curve) is obtained by plotting the potential as a function of current density (I) (or log I) for each measured point. The potentiodynamic polarization curve can be used to calculate the metal's corrosion potential and rate in any given condition (Tafel slope).

Applications of corrosion testing potentiodynamic potentiostat galvanostat CS350M

● Corrosion study and corrosion resistance evaluation of metals; quick evaluation of corrosion inhibitors, coatings, and cathodic protection efficiency

● Study of Energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials

● Electrocatalysis (HER, OER, ORR, CO2RR, NRR)

● Electrosynthesis, electroplating/electrodeposition, anode oxidation, electrolysis

Key harware features of corrosion testing potentiodynamic potentiostat galvanostat CS350M

- Built-in EIS/FRA, EIS Frequency range: 10μHz~1MHz

- High bandwidth and high input impedance amplifier

- Built-in FPGA DDS signal synthesizer

- High-power Potentiostat/Galvanostat/ZRA;
- Current control range: ±2A

- Potential control range: ±10V;

- Compliance voltage: ±21V
- Potential resolution: 10μV;

- Current resolution 1pA

Standard supply of corrosion testing potentiodynamic potentiostat galvanostat CS350M

potentiostat galvanostat CS350M CS350M*1

CS studio software *1

Power cable x1

USB cable x1

Cell/electrode cable x2

Dummy cell(1kΩ||100µF) x1

Manual

Application of corrosion testing potentiodynamic potentiostat galvanostat CS350M

Corrosion: corrosion testing potentiodynamic potentiostat galvanostat CS350M includes all the electrochemical techniques for corrosion measurement such as OCP, polarization curve (potentiodynamic), EIS, Cyclic polarization CPP (passivation curve), Electrochemical Potentiokinetic Reactivation (EPR), Hydrogen diffusion test, ZRA, Electrochemical noise, etc. It can be used to study metal corrosion mechanism and corrosion resistance, and evaluate the coating durability and sacrificial anode current efficiency. It can also be used for rapid screening of corrosion inhibitors, fungicides, etc.

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion TestingPotentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing

Left: Polarization curves of Ti-alloy& stainless steel in 3%NaCl solution

Right: EN of low-carbon steel in 0.05mol/LCl+0.1mol/LNaHCO3

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing

Corrosion testing potentiodynamic potentiostat galvanostat CS350M uses correlation integral algorithm and dual-channel over- sampling technique, and has strong anti-interference ability. The internal resistance of the instrument is up to 1013Ω. It's suitable for EIS measurements of high-impedance system (such as coating, concrete etc)

Salt spray aging test of high impedance coating

Advantages

Full floating

All Corrtest potentiostats / galvanostats incl. corrosion testing potentiodynamic potentiostat galvanostat CS350M are designed as full-floating, and can be used for electrochemical study of working electrode connecting to earth, such as autoclave, metal part in bridge, concrete

Real-time data storage

Experiment data can be stored in real time. Even if the test is interrupted by a power failure, the data will be automatically saved.

EIS

● Corrtest corrosion testing potentiodynamic potentiostat galvanostat CS350M uses correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. The internal resistance of the instrument is up to 1013Ω. It's suitable for EIS measurements of high-impedance system (such as coating, concrete etc.)

Multi electrode system

● Corrosion testing potentiodynamic potentiostat galvanostat CS350M supports 2-, 3-, 4-electrode system, can be used to test battery internal resistance or 4-electrode thin film impedance measurement

● With Zero resistance ammeter for galvanic current measurement

Software development kit(SDK)

We can provide secondary development interfaces,API general interfaces and development examples, and can realize data call for Labview, C, C++, C#, VC and other program, which is convenient for secondary development and test methods customization.

Versatile data analysis

CS Studio is the software for corrosion testing potentiodynamic potentiostat galvanostat CS350M for experiment control and data analysis. It can do: multi-parameter Tafel curve fitting, derivation, integration and peak height analysis of voltammetric curve, EIS equivalent circuit customization and impedance spectrum fitting, etc.

● Multi-parameters Polarization curve

● EIS fitting

● Electrochemical noise analysis

● Pseudo capacitance calculation

● GCD specific capacitance, efficiency

● Mott-Schottky plot analysis

● CV analysis

Combination test

CS studio software supports the combination test for various experiments to achieve flexible and

unattended test. You can set the parameters for each experiment in advance, and set the intervals, wait time etc between each experiment.

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing

Combination Test: corrosion tests

Software Features of corrosion testing potentiodynamic potentiostat galvanostat CS350M

Tafel plot and corrosion rate: CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the ECN measurements.

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing

EIS analysis: Bode, Nyquist, Mott-Schottky plot

During EIS data analysis, there is built-in fitting function to draw the custom equivalent circuit.

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing

Techniques of corrosion testing potentiodynamic potentiostat galvanostat CS350M

Stable polarization

  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)

Corrosion Measurements

  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)

Electrochemical Impedance Spectroscopy (EIS)

  • Potentiostatic EIS (Nyquist, Bode)
  • Galvanostatic EIS
  • Potentiostatic EIS (Optional freq.)
  • Galvanostatic EIS(Optional freq.)
  • Mott-Schottky
  • Potentiostatic EIS vs. Time (Single freq.)
  • Galvanostatic EIS vs. Time (Single freq.)

Transient Polarization

  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)

Chrono Method

  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)

Voltammetry

  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV) #
  • Square Wave Voltammetry (SWV) #
  • Differential Pulse Voltammetry (DPV) #
  • Normal Pulse Voltammetry (NPV) #
  • Differential Normal Pulse Voltammetry (DNPV) #
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)

Battery test

  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging(PCD)
  • Potentiostatic Intermittent Titration Technique (PITT)
  • Galvanostatic Intermittent Titration Technique (GITT)

Amperometric

  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)

Extensions

  • Electrochemical Stripping/ Deposition
  • Bulk Eletrolysis with Coulometry (BE)
  • Rs Measurement

# There is the corresponding stripping method.


Product Tags:

Potentiodynamic Potentiostat Galvanostat

      

Corrosion Testing Potentiostat Galvanostat

      

Potentiostat Galvanostat CS350M

      
Best Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing wholesale

Potentiodynamic Potentiostat Galvanostat CS350M For Corrosion Testing Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Wuhan Corrtest Instruments Corp., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0